Implant encyclopedia

Medentis® — implant systems

8 systems in the DentGrow catalogue.

Country
Germany

Medentis systems

SystemConnectionØLengthStatus
ICX-Active LiquidPlatforms: ICX Standard (cónica interna hexagonal — linha protética comum aos Ø3,45 a Ø4,8), ICX 3.3 mm (linha protética própria do Ø3,3)desconhecidoMorse Taper3.3–4.8 mm8–15 mmIn production
ICX-Active MasterPlatforms: ICX Standard (cónica interna hexagonal — linha protética comum aos Ø3,45 a Ø4,8), ICX 3.3 mm (linha protética própria do Ø3,3)desconhecidoMorse Taper3.3–4.8 mm8–15 mmIn production
ICX-Active Master TLPlatforms: ICX Standard (cónica interna hexagonal — linha protética comum aos Ø3,45 a Ø4,8), ICX 3.3 mm (linha protética própria do Ø3,3)desconhecidoMorse Taper3.3–4.8 mm8–12.5 mmIn production
ICX-Active WhitedesconhecidoInternal connection (other)4.1 mm8–15 mmIn production
ICX-DiamondPlatforms: ICX Standard (cónica interna hexagonal — linha protética comum aos Ø3,45 a Ø4,8), ICX 3.3 mm (linha protética própria do Ø3,3)desconhecidoMorse Taper3.3–4.8 mm4.9–15 mmIn production
ICX-MiniPlatforms: Mini 2.9 mm (ligação própria do ICX-Mini — cabeça esférica t-bona e ICX-Maximus)desconhecidoInternal connection (other)2.9 mm8–12.5 mmIn production
ICX-PremiumPlatforms: ICX Standard (cónica interna hexagonal — linha protética comum aos Ø3,45 a Ø4,8), ICX 3.3 mm (linha protética própria do Ø3,3)desconhecidoMorse Taper3.3–4.8 mm8–15 mmIn production
ICX-Premium TLPlatforms: ICX Standard (cónica interna hexagonal — linha protética comum aos Ø3,45 a Ø4,8), ICX 3.3 mm (linha protética própria do Ø3,3)desconhecidoMorse Taper3.3–4.8 mm4.9–12.5 mmIn production

Official catalogues

The links open the document on the manufacturer's website.

The brand and product names mentioned here belong to their respective owners and are used for identification only. DentGrow has no connection with these manufacturers and is not sponsored or endorsed by them.

Technical information is indicative and intended to help with identification. It does not replace the packaging, the clinical record or the manufacturer's catalogue, which always prevails. Found an error? Let us know via Manufacturers' catalogues.

Some of the data comes from AccessGUDID, a public database of the National Library of Medicine (NLM), National Institutes of Health, Department of Health and Human Services. The NLM is not responsible for this product and does not endorse or recommend it. Other data comes from EUDAMED (© European Union), reused under the CC BY 4.0 licence, with changes.