Keystone Dental® Oct (Octógono Interno) — Southern Implants®

Keystone Dental Oct (Octógono Interno) — Southern Implants: Internal Octagon connection · platforms Ø3.3 mm, Ø4.0 mm, Ø4.8 mm, Ø5.7 mm · Ø 3.3–5.7 mm · in production. Technical sheet to identify the implant.

Technical sheet

In production
Manufacturer
Southern Implants®Sold under the Keystone Dental® brand, made by Southern Implants®. Source: Registo de estabelecimento da Keystone Dental na FDA (nº 3011936113): os 510(k) destes sistemas têm como requerente a Southern Implants, Inc. — K070905 e K070841 (Tri-Nex), K082651 (Co-Axis), K071161 (MAX-TL) e K093562 (Zygomatic) — e os códigos de catálogo são os mesmos nas duas marcas.
Country
United States
Platforms
Ø3.3 mm, Ø4.0 mm, Ø4.8 mm, Ø5.7 mm
Diameters
3.3 · 4 · 4.1 · 4.9 · 5 · 5.7 mm
Lengths
6 · 8 · 10 · 12 · 14 mm
Body shape
hybrid
Apex shape
tapered
Type
Bone level
Material
Titânio puro grau 4 de alta resistência (fabrico Southern Implants®)
Surface
SInergy: superfície rugosa obtida por jateamento com alumina (Al₂O₃, 110 µm), «moderadamente rugosa» (Sa 1,4–1,6 µm)

References

ReferenceØLengthGTIN
ITC3063.3 mm6 mmD768ITC3060
ITC3083.3 mm8 mmD768ITC3080
ITC3103.3 mm10 mmD768ITC3100
ITC3123.3 mm12 mmD768ITC3120
ITC3143.3 mm14 mmD768ITC3140

+25

references in this system

3.3–5.7 mm × 6–14 mm

See all 30 references

30 days free

Same connection type, other brands

Systems with a Internal Octagon connection and similar diameters, to help identify an implant. It does not mean they share components: confirmed compatibilities are in your account.

Spotted wrong data on this sheet?

Tell us what — we check every report against the manufacturer's catalogue.

The brand and product names mentioned here belong to their respective owners and are used for identification only. DentGrow has no connection with these manufacturers and is not sponsored or endorsed by them.

Technical information is indicative and intended to help with identification. It does not replace the packaging, the clinical record or the manufacturer's catalogue, which always prevails. Found an error? Let us know via Manufacturers' catalogues.

Some of the data comes from AccessGUDID, a public database of the National Library of Medicine (NLM), National Institutes of Health, Department of Health and Human Services. The NLM is not responsible for this product and does not endorse or recommend it. Other data comes from EUDAMED (© European Union), reused under the CC BY 4.0 licence, with changes.