Keystone Dental® Oct MAXIT™ (molar) — Southern Implants®

Keystone Dental Oct MAXIT (molar) — Southern Implants: Internal Octagon connection · platforms Ø4.8 mm (implante Ø7.0), Ø6.5 mm (implantes Ø8.0 e Ø9.0) · Ø 7–9 mm · in production. Technical sheet to identify the implant.

Technical sheet

In production
Manufacturer
Southern Implants®Sold under the Keystone Dental® brand, made by Southern Implants®. Source: Registo de estabelecimento da Keystone Dental na FDA (nº 3011936113): os 510(k) destes sistemas têm como requerente a Southern Implants, Inc. — K070905 e K070841 (Tri-Nex), K082651 (Co-Axis), K071161 (MAX-TL) e K093562 (Zygomatic) — e os códigos de catálogo são os mesmos nas duas marcas.
Country
United States
Platforms
Ø4.8 mm (implante Ø7.0), Ø6.5 mm (implantes Ø8.0 e Ø9.0)
Diameters
7 · 8 · 9 mm
Lengths
7 · 9 · 11 mm
Body shape
hybrid
Apex shape
tapered
Type
Other
Material
Titânio puro grau 4 de alta resistência (fabrico Southern Implants®)
Surface
SInergy: superfície rugosa obtida por jateamento com alumina (Al₂O₃, 110 µm), «moderadamente rugosa» (Sa 1,4–1,6 µm)

References

ReferenceØLengthGTIN
MAXIT7-77 mm7 mmD768MAXIT770
MAXIT7-97 mm9 mmD768MAXIT790
MAXIT7-117 mm11 mmD768MAXIT7110
MAXIT8-78 mm7 mmD768MAXIT870
MAXIT8-98 mm9 mmD768MAXIT890

+4

references in this system

7–9 mm × 7–11 mm

See all 9 references

30 days free

Same connection type, other brands

Systems with a Internal Octagon connection and similar diameters, to help identify an implant. It does not mean they share components: confirmed compatibilities are in your account.

Spotted wrong data on this sheet?

Tell us what — we check every report against the manufacturer's catalogue.

The brand and product names mentioned here belong to their respective owners and are used for identification only. DentGrow has no connection with these manufacturers and is not sponsored or endorsed by them.

Technical information is indicative and intended to help with identification. It does not replace the packaging, the clinical record or the manufacturer's catalogue, which always prevails. Found an error? Let us know via Manufacturers' catalogues.

Some of the data comes from AccessGUDID, a public database of the National Library of Medicine (NLM), National Institutes of Health, Department of Health and Human Services. The NLM is not responsible for this product and does not endorse or recommend it. Other data comes from EUDAMED (© European Union), reused under the CC BY 4.0 licence, with changes.